Leave A Message

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit
Home OEM reagents

Inflammation Panel:IL6 OEM kit Adopting Chemiluminescence assay platforms

Inflammation Panel:IL6 OEM kit Adopting Chemiluminescence assay platforms

Interleukin-6 (IL-6) is a pivotal cytokine in inflammatory and immune responses. It promotes B-cell antibody production, T-cell proliferation, and IL-2 expression, while regulating the growth and differentiation of diverse cell types. Beyond its central roles in immune regulation, acute-phase responses, and hematopoiesis, IL-6 is crucial for host defense against infections. Marked alterations in IL-6 levels closely correlate with disease activity, tumor progression, transplant rejection severity, and therapeutic efficacy.

 

Bulk reagents are available with matching raw materials. 

 

 

 

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

  • Brand :

    QYM,SURFTECH
  • Item No :

    IL6-1
  • Order(MOQ) :

    On request
  • Payment :

    T/T
  • Product Origin :

    China
  • Color :

    R1 should be a colorless to pale yellow transparent liquid; R2 should be a milky white suspension.
  • Shipping Port :

    Hefei or other ports
  • Lead Time :

    On request
  • Weight :

    On request

IL6 OEM reagent

Product Specifications

  

Product Name IL6 OEM reagent (chemiluminescence platforms)
Application: It is applied 
Detection Principle

Two-antibody sandwich immunoassay 

Sample Type: 

Serum/ plasma

Calibrator Component: 

Recombinant Antigen

Incubation Time

10 min (One-step Delay Method)

Analytical Sensitivity

1.5 pg/mL

Measuring Range

1.5–5000 pg/mL

Traceability Reference Material

Roche

Precision

Intra-assay CV ≤5%; Inter-assay CV ≤10%

Method comparison

Correlation coefficient r>0.975 vs. Roche
Hook 200,000 pg/mL
Package Size

on request

Storage/Shipping Store sealed and protected from light at 2 °C to 8 °C
Shelf Life 12 months
    

 

Product Advantages

1.Sensitivity up to 1.5 pg/mL; measured performance superior to industry peers.

2.Linearity up to 5000 pg/mL, top-tier industry standard.

3.Precision matches global leaders and exceeds China competitors.

4.Free of prominent high-dose hook effect at 50000 pg/mL.

5.High correlation vs Roche, R²>0.975.

 

 

           Sensitivity Analysis                          Batch precision test                                      

          

 

            Hige-Dose Hook Test                                            

       

 

Application Scenarios

 

 

Interleukin-6 (IL-6) is a pivotal cytokine in inflammatory and immune responses. It promotes B-cell antibody production, T-cell proliferation, and IL-2 expression, while regulating the growth and differentiation of diverse cell types. Beyond its central roles in immune regulation, acute-phase responses, and hematopoiesis, IL-6 is crucial for host defense against infections. Marked alterations in IL-6 levels closely correlate with disease activity, tumor progression, transplant rejection severity, and therapeutic efficacy.

 

 

--------------占位---------------

FAQ

Is the analytical sensitivity high enough to detect low baseline IL-6 levels in normal individuals or early-stage inflammation?

Yes. With a Limit of Detection (LoD)  ≤1.5 pg/mL, the assay reliably quantifies low baseline levels for early cytokine release monitoring.

 

 
 
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

Inflammation Panel:IL6 OEM kit Adopting Chemiluminescence assay platforms
Inflammation Panel:IL6 OEM kit Adopting Chemiluminescence assay platforms

Interleukin-6 (IL-6) is a pivotal cytokine in inflammatory and immune responses. It promotes B-cell antibody production, T-cell proliferation, and IL-2 expression, while regulating the growth and differentiation of diverse cell types. Beyond its central roles in immune regulation, acute-phase responses, and hematopoiesis, IL-6 is crucial for host defense against infections. Marked alterations in IL-6 levels closely correlate with disease activity, tumor progression, transplant rejection severity, and therapeutic efficacy.   ★Bulk reagents are available with matching raw materials.                                     

Read More
Inflammation Panel:PCT OEM kit Adopting Chemiluminescence assay platforms
Inflammation Panel:PCT OEM kit Adopting Chemiluminescence assay platforms

Interleukin-6 (IL-6) is a pivotal cytokine in inflammatory and immune responses. It promotes B-cell antibody production, T-cell proliferation, and IL-2 expression, while regulating the growth and differentiation of diverse cell types. Beyond its central roles in immune regulation, acute-phase responses, and hematopoiesis, IL-6 is crucial for host defense against infections. Marked alterations in IL-6 levels closely correlate with disease activity, tumor progression, transplant rejection severity, and therapeutic efficacy.   ★Bulk reagents are available with matching raw materials.                                         

Read More
Inflammation Panel:HBP OEM kit Adopting Chemiluminescence assay platforms
Inflammation Panel:HBP OEM kit Adopting Chemiluminescence assay platforms

Heparin-Binding Protein (HBP), a neutrophil-derived granule protein, serves as an early diagnostic biomarker for infectious diseases, particularly severe bacterial infections. Serum/plasma HBP levels rise significantly in bacterial infections, whereas non-bacterial infections do not induce such an elevation. Heparin-Binding Protein (HBP) is applied for the early identification, risk stratification, and prognosis assessment of severe bacterial infections and sepsis, as well as the differential diagnosis of acute inflammatory conditions and localized infection-induced vascular leakage. HBP OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct structural epitopes on the HBP molecule to capture plasma or serum HBP, delivering high sensitivity and exceptional specificity without cross-reactivity to other neutrophil granule proteins. Calibrated with high-purity recombinant HBP antigen, the assay provides accurate, reliable, and stable quantitative results. Serving as an early-warning biomarker for acute vascular leakage and organ failure, it supports timely clinical intervention, triage in emergency and intensive care units (ICU), and dynamic therapeutic efficacy monitoring in severe infectious diseases.   ★Bulk reagents are available with matching raw materials.                                     

Read More
Gastric Function Panel:G17 OEM kit Adopting Chemiluminescence assay platforms
Gastric Function Panel:G17 OEM kit Adopting Chemiluminescence assay platforms

Gastrin-17 (G-17) is applied for the screening, risk stratification, and auxiliary diagnosis of chronic atrophic gastritis, gastric antral mucosal atrophy, and gastric cancer, as well as the non-invasive monitoring of gastric acid status, Helicobacter pylori (H. pylori) infection, and long-term proton pump inhibitor (PPI) therapy. G17 OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct structural epitopes on the G-17 molecule to capture serum or plasma G-17, delivering high sensitivity and exceptional specificity without cross-reactivity to other gastrin isoforms or cholecystokinin (CCK). Calibrated with high-purity recombinant G-17 antigen, the assay provides accurate, reliable, and stable quantitative results. Serving as a crucial non-invasive biomarker for gastric antral secretory function, when combined with PG I, PG II, and the PGI/PGII ratio (PGR) in the "serological gastric biopsy" panel, it supports precise location-specific identification of gastric mucosal lesions, non-invasive gastric cancer risk stratification, and dynamic clinical management.   ★Bulk reagents are available with matching raw materials.                                   

Read More
Gastric Function Panel:PGI OEM kit Adopting Chemiluminescence assay platforms
Gastric Function Panel:PGI OEM kit Adopting Chemiluminescence assay platforms

Pepsinogen I (PGI) is applied for the screening, risk stratification, and auxiliary diagnosis of chronic atrophic gastritis and gastric cancer, as well as the non-invasive evaluation of gastric mucosal secretory function and gastric body atrophy. PGI OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct structural epitopes on the PG I molecule to capture serum or plasma PG I, delivering high sensitivity and exceptional specificity without cross-reactivity to Pepsinogen II (PG II). Calibrated with high-purity recombinant PG I antigen, the assay provides accurate, reliable, and stable quantitative results. Serving as a primary non-invasive biomarker for gastric acid secretory capacity, when combined with PG II and the PGI/PGII ratio (PGR), it supports early identification of gastric mucosal atrophy, non-invasive gastric cancer risk stratification, and clinical therapeutic monitoring.   ★Bulk reagents are available with matching raw materials.                                         

Read More
Gastric Function Panel:PGII OEM kit Adopting Chemiluminescence assay platforms
Gastric Function Panel:PGII OEM kit Adopting Chemiluminescence assay platforms

Pepsinogen II (PGII) is applied for the screening, risk stratification, and auxiliary diagnosis of chronic atrophic gastritis, peptic ulcer diseases, and gastric cancer, as well as the dynamic monitoring of Helicobacter pylori (H. pylori) eradication therapy and gastric mucosal status. PGII OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct structural epitopes on the PG II molecule to capture serum or plasma PG II, delivering high sensitivity and exceptional specificity without cross-reactivity to Pepsinogen I (PG I). Calibrated with high-purity recombinant PG II antigen, the assay provides accurate, reliable, and stable quantitative results. Serving as a key non-invasive biomarker for gastric health evaluation, when combined with PG I and the PGI/PGII ratio (PGR), it supports early identification of gastric mucosal lesions, non-invasive gastric cancer risk assessment, and clinical therapeutic efficacy monitoring.   ★Bulk reagents are available with matching raw materials.                                           

Read More
Cardiovascular Panel: D-Dimer OEM kit Adopting Chemiluminescence assay platforms
Cardiovascular Panel: D-Dimer OEM kit Adopting Chemiluminescence assay platforms

D-Dimer is applied for the rule-out diagnosis of deep vein thrombosis (DVT) and pulmonary embolism (PE), as well as the auxiliary diagnosis, risk evaluation, and dynamic monitoring of disseminated intravascular coagulation (DIC) and hypercoagulable states. D-Dimer OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct cross-linked D-Dimer domain epitopes on fibrin degradation products to capture plasma D-Dimer, delivering high sensitivity and exceptional specificity without cross-reactivity to fibrinogen. Calibrated with high-purity recombinant D-Dimer antigen, the assay provides accurate, reliable, and stable quantitative results. Serving as a crucial clinical biomarker for thrombotic disorders, it supports rapid emergency rule-out, risk assessment, and therapeutic response monitoring in thrombolytic therapy. As a classic thrombosis marker, D-Dimer is widely used clinically to rule out venous thromboembolism (VTE). It also supports diagnosis and therapeutic monitoring of disseminated intravascular coagulation (DIC) and malignant tumors, as well as evaluation of coagulation disorders, making it one of the most commonly ordered coagulation tests by clinicians. ★Bulk reagents are available with matching raw materials.                               

Read More
Cardiovascular Panel: ST2 OEM kit Adopting Chemiluminescence assay platforms
Cardiovascular Panel: ST2 OEM kit Adopting Chemiluminescence assay platforms

Suppression of Tumorigenicity 2 (ST2) is applied for risk stratification, disease severity evaluation, and prognosis assessment of patients with acute and chronic heart failure, as well as cardiac fibrosis and remodeling. ST2 OEM kit utilizes a two-antibody sandwich immunoassay and is applicable to chemiluminescence platforms. Specific monoclonal antibodies target distinct epitopes on the soluble ST2 molecule to capture plasma sST2, delivering high sensitivity and exceptional specificity. Calibrated with high-purity recombinant sST2, the assay provides accurate, reliable, and stable quantitative results. Unaffected by age, BMI, or renal function, it serves as a valuable novel biomarker for cardiac fibrosis and biomechanical strain, supporting personalized risk prediction and dynamic therapeutic monitoring in heart failure management.   ★Bulk reagents are available with matching raw materials.   

Read More

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

Home

products

whatsApp

contact